ホームページ / 全て / Safety Products / Laser Distance Displacement Sensor /

Laser measurement distance|Laser Ranging Sensor|DADISICK

Laser measurement distance|Laser Ranging Sensor|DADISICK
Laser measurement distance|Laser Ranging Sensor|DADISICKLaser measurement distance|Laser Ranging Sensor|DADISICKLaser measurement distance|Laser Ranging Sensor|DADISICKLaser measurement distance|Laser Ranging Sensor|DADISICKLaser measurement distance|Laser Ranging Sensor|DADISICK

Laser measurement distance|Laser Ranging Sensor|DADISICK

カタログLaser Distance Displacement Sensor
ブランドDADISICK
製品の規格DA-Y & DB-Y Series
Measuring frequency:1Hz-40Hz
Communication interface:RS232/RS485 (switchable)
Laser type:Class II, 660±15nm, ≤1mW
Measurement resolution:1mm
Power supply:DC15~30V
Power consumption:<3.0W
Protection grade:IP67
更新時間2024/11/21
詳細情報
DADISICK Laser ranging sensor
DA-Y & DB-Y Series
Laser Ranging Sensor Models comparison
Type A
Models
DA-Y10
DA-Y20
DA-Y30
DA-Y50
DA-Y100
Measuring range
0.2-10m
0.2-20m
0.2-30m
0.2-50m
0.2-100m
Output mode
Digital quantity & switch quantity
Type B
Models
DB-Y10
DB-Y20
DB-Y30
DB-Y50
DB-Y100
Measuring range
0.2-10m
0.2-20m
0.2-30m
0.2-50m
0.2-100m
Voltage/current output
Can be set to 0~5V / 0~10V / 4~20mA / 0~20mA /0~24mA output *Note 2
Voltage output error
0.2%+0.5mV
Current output error
0.2%+0.005mA
Output mode
Digital quantity, switch quantity, analog quantity
Specification
Communication interface
RS232/RS485 (switchable)
Measuring frequency
1Hz-40Hz
Laser type
Class II, 660±15nm, ≤1mW
Measurement resolution
1mm
Measurement error
±(2mm+d * one ten thousandth) *Note 1
Indicator light
Red laser
Spot size
@1m∅6mm; @10m∅8mm;
@20m∅12mm; @30m∅16mm;
Display
128x32 dot matrix screen
Backlight off time
30 minutes (can be set to normally on)
Operating mode
Off measurement, continuous measurement
Transistor switch output
2 channels (cannot exceed DC36V 0.5A) *Note 3
Power supply
DC15~30V
Power consumption
<3.0W
Protection grade
IP67
Shell material
Die-cast zinc alloy
Working temperature
-10°C~50°C
Storage temperature and humidity
-20°C~60°C, 20%~85%RH
Overheating protection
When the body temperature is higher than 70°C, the measurement will be shut down and when the temperature is lower than 70°C, the measurement will be resumed.
Dimension
88.45x40x59.3mm (including connection base)
Notes
*Note 1: When [Speed Level] is 1.
"d" represents the actual distance. In harsh environments, such as when the sun is too strong and the ambient temperature fluctuates too much, there will be a large error in the measurement results. In this case, the effect is better when used with a target reflector.
*Note 2: Current and voltage can' t be output at the same time.
*Note 3: If the external DC output of the transistor switch exceeds the limited voltage or current, it may cause permanent damage to the instrument.
DIMENSION                                                                                                                                                                       
DIMENSION
WIRING DIAGRAM                                                                                                                                                                                    
RS485 Wiring Method
Safety Light Curtain Cable Description
RS232 Wiring Method
Safety Light Curtain Signal Output Selection
DOCUMENTS & DOWNLOADS                                                                                                                                                                  
CATALOGUE

DA-Y&DB-Y series laser displacement sensor
DA-Y&DB-Y series user's manual
評価
  • 読み込んでいます...
関連製品
    求める品の情報をご連絡ください
    *Email
    お名前
    *題名
    *内容
    アップロード
    • .rar/.zip/.jpg/.png/.gif/.doc/.xls/.pdf のみをサポート、最大 20M