ホームページ / 全て / Safety Relay /

Safety Relay – A Safety Solution That Meets Most Automation Industry Requirements

Safety Relay – A Safety Solution That Meets Most Automation Industry Requirements

2025/3/4

Safety Relay – A Safety Solution That Meets Most Automation Industry Requirements

Safety relay/safety relays DADISICK

Functional Definition of Safety Relays

Safety relays are critical execution units in functional safety systems. Through redundant circuit design, real-time self-testing, and force-guided contact mechanisms, they ensure reliable disconnection of equipment power sources and activation of a safe shutdown when hazardous events (e.g., emergency stop activation, safety light curtain interruption) or internal faults are detected. They support multi-channel inputs (e.g., dual-contact emergency stop buttons, safety door interlocks) and logical combinations (e.g., two-hand control, zone interlocking), complying with the Performance Level (PL) requirements defined in ISO 13849-1.

With the advancement of industrial networking, safety relays integrated with protocols such as PROFIsafe and EtherNet/IP CIP Safety enable real-time data exchange with higher-level control systems. They provide fault diagnostics, event logging, and predictive maintenance support, aligning with the dual demands of safety and availability in smart manufacturing applications (e.g., automotive welding lines, safety control systems for packaging machinery).

Relying on Safety Technology Standards

Our safety relays are engineered for the highest level of industrial safety, meeting stringent global standards. 

For Example: Safety Relay Module LS-2A4S

Performance Level (PL): PL e, compliant with EN ISO 13849.

Safety Category (Cat.): Cat. 4, compliant with EN ISO 13849.

MTTFd: ≥ 20 years, compliant with EN ISO 13849.

Diagnostic Coverage (DC): ≥ 99%, compliant with EN ISO 13849.

Safety Integrity Level (SIL): SIL 3, compliant with IEC 61508 and IEC 62061.

Hardware Fault Tolerance (HFT): 1, compliant with IEC 61508 and IEC 62061.

Safe Failure Fraction (SFF): ≥ 99%, compliant with IEC 61508 and IEC 62061.

PFHD: ≤ 1.86E-9/h, compliant with IEC 61508 and IEC 62061.

Stop Category: 0, compliant with EN 60204-1.
Benefits of the safety relays LS series

Safety Relay Wiring Diagram

Quickly and easily integrate various safety sensors into the safety circuits of machines and systems.

Typical Safety Relay Wiring Diagrams:
Safety Relay LS-2A4S
Safety Relay Wiring Method with Four Emergency Stop Button Inputs
Safety Relay LS-3A1B.C
Safety Relay Wiring Method with Dual-Channel Emergency Stop Button Input
Four Emergency Stop Button Inputs with Safety Relay Module
Description:
Input Components: CH1 (Emergency Stop Button); CH2 (Emergency Stop Button); CH3 (Reset Button)
Input Components: CH4 (Emergency Stop Button); CH5 (Emergency Stop Button); CH6 (Reset Button)
Control Logic: CH1 & CH2, CH4 & CH5
Reset Mode: Manual Reset
Output Delay: 0 s

Safety Category: Cat. 4
Performance Level: PL e
Safety Integrity Level: SIL 3
Dual-Channel Emergency Stop Button Input with Safety Relay
Description:
Dual-Channel Emergency Stop Button Input
Short-Circuit Monitoring Between Channels
Manual Reset
With Output Contact Feedback
Suitable for the Highest Safety Category 4

Components:
S1: Dual-Channel Emergency Stop Button
S3: Reset Button
K7, K8: Contactors
F1: External Fuse Protection
M1: Motor

How to Find the Right Safety Relay for Your Application

Safety relay working principle
1️⃣Safety Zones/Number of Safety Functions
2️⃣Expandable Safety Relays
3️⃣Power Supply Voltage
4️⃣Configurable Parameters
5️⃣Compact Design

Safety Relay Selection
Safety Relay Features Overview
DADISICK Safety Relay Features Overview
LS-3A1B.C – Cost-effective solution
Suitable for various machinery, compatible with emergency stop buttons, safety doors, and PNP-type safety light curtains.
▪️Dimension: 114.5 × 99 × 22.5 mm
▪️Outputs: 3 NO (Normally Open) safety outputs, 1 NC (Normally Closed) auxiliary output
▪️Functions: Supports single/dual-channel operation, manual/automatic reset, and short-circuit monitoring between channels
▪️Key Feature: Economical and efficient, ideal for standard machine safety applications


LS-2A4S – Safety relay module
Designed for intelligent safety control, supporting multiple switching-type safety device inputs.
▪️Dimension: 114.5 × 99 × 45 mm
▪️Inputs: Supports up to 6 safety device inputs (such as emergency stop buttons, safety doors, two-hand switches, etc.)
▪️Outputs: 2 relay safety outputs, 4 semiconductor safety outputs
▪️Functions: Safety logic can be configured via software to meet various application requirements
▪️Key Feature: Flexible and expandable, suitable for complex safety systems

Ter-A – Multi-Type Safety Sensor Compatibility
Supports a wide range of safety sensors, making it ideal for multi-sensor applications.
▪️Dimension: 112 × 99.5 ×22.6 mm
▪️Compatible Devices: Emergency stop buttons, Safety switches, Safety door locks, Safety light curtains, Safety scanners, Safety sensors, Safety edges, Safety mats, Two-hand switches
▪️Key Feature: Highly compatible with various safety detection devices, suitable for complex industrial safety control

LS-A – Economical Safety Relay
Designed for basic safety control, compatible with standard safety devices such as emergency stop buttons and safety door locks.
▪️Dimension: 114.5 × 99 × 22.5 mm
▪️Compatible Devices: Emergency stop buttons, Safety switches, Safety door locks, Safety light curtains, Safety scanners, Two-hand switches, Safety sensors
▪️Key Feature: High cost-performance ratio and simple design, ideal for standard safety applications

QSRN – Specifically designed for safety light curtains
Specifically designed for monitoring safety light curtains, ensuring reliable detection performance.
▪️Dimension: 117 × 100 × 22.5 mm


Recommended Safety Relays

Safety Relay LS-2A4S
Supports up to 6 safety device inputs, 2 relay safety outputs, and 4 semiconductor safety outputs. Configurable via setup software to define safety control logic, meeting various on-site application requirements.
Safety Relay LS-3A1B.C
A safety relay with 3 NO (normally open) safety output contacts and 1 NC (normally closed) auxiliary output contact. It supports single or dual-channel operation, manual or automatic reset, and features short-circuit monitoring between channels.
Safety Relay Ter-A
3NO + 1NC safety contacts
Auto/manual reset option
Redundant self-monitoring circuit ensures reliability
Automatic contact testing in each cycle
Safety Relay LS-A
3NO + 1NC safety contacts
Auto/manual reset option
Configurable for E-stop, light curtains, door locks, and two-hand control switches

Related Safety Sensors

QCE42-30-1230 2BB|Safety Light Curtain|DADISICK
Beam spacing: 30mm Number of optical axes: 42 Protection height: 1230mm Safety light curtain outputs (OSSD)2 PNP
DT11 series|PVC safety Mats|DADISICK
Safety carpet is a technology that monitors the pressure distribution on the carpet through pressure sensing.
OX-W2-2O/2C-GC-J | Safety Locking Devices | DADISICK
Used for monitoring places such as safety doors and windows.
DB-PSE series|Safety Edges|DADISICK
Safety Edges is a technology that monitors the pressure distribution on the carpet through pressure sensing.

DADISICKは、常にハイエンドのセキュリティセンサー製品に注力し、技術研究開発と製品革新に注力しています。当社の製品は、自動化設備、機械製造、自動車製造、電子機器製造などの業界で広く使用されており、産業事故の発生率を減らし、従業員の安全を確保するのに役立っています。当社は、市場の需要を満たす新製品を継続的に導入し、企業の安全生産をサポートしています。

*交換サービス:競争の激しい市場では、企業は市場シェアを維持するために製品を継続的に改良する必要があります。当社は安全センサーの交換サービスを提供しています。

*製品ラインの改善・調整:企業が新規市場に参入したり、重点をシフトしたりする際には、製品ラインを改良する必要が生じる場合があります。当社は、この移行のための安全センサー製品と技術サポートを提供します。

*オートメーション産業機器の動作状態を監視し、機械の動作を速やかに停止または調整して、生産プロセスの安全性を確保します。

*機械製造機械動作コンポーネントを監視し、潜在的な危険を防ぎ、従業員の安全と生産ラインの円滑な運用を守ります。

*自動車製造安全は、車両組立ラインにおける高リスクプロセスを監視し、作業者の安全性と生産効率を向上させます。

*化学産業生産環境をリアルタイムで監視し、有毒物質や危険物質の取り扱いの安全性を確保します。

*食品・飲料業界生産ラインの設備の動作を監視し、食品の汚染や廃棄を防止します。

*物流と倉庫AGV ナビゲーションと障害物回避に使用され、商品の安全な輸送を保証します。

*木材加工、繊維、製紙、印刷、ゴム、プラスチックなどの業界では、安全センサーがさまざまな生産プロセスを監視し、安全性と効率性を確保するために使用されています。